YZ - 200B High Frequency X-Ray 200mA

YZ - 200 B ( 200 mA )
MAIN TECHNICAL PARAMETER
Single bed with single bulb
Design according to the electric mechanism of middle-size machine, with complete and reasonable function
High-voltage system is of split structure with high voltage generator of full wave rectification, independent X-ray tube unit, large output power and reliable and stable operation
Power voltage (V) photograph kilovolt (KV) and infinitely variable control
Be equipped with the Monistat for the filament of X-ray tube and space complementary to ensure the stable and exact output
Be equipped with capacity limit protective circuit --- kV mAS interlock limit protective
The timer circuit grades according to R 10 priority coefficient has an exact time control
The photographic flat bed has a vibrating ray-filter
The pillar has only the bottom track with easy installation
General Photography
Filter-ray device photography
ITEM
CONTENT
                                    INDEX
Demand of power supply
Voltage
220 V / 380 V + 10% single Phase 220 V/380 V + 10%
Freguency
50 Hz + 0.5 Hv
Capacity
10 KVA
Internal resistance
380 V : 2 W ; 220V : 0.6 W 0 2W at 380V;0.6W at 220 V
Photography
Voltage
50 ~ 90 KV                      50 ~ 100 KV
Current
25 mA       50 mA        75 mA      100 mA    125 mA
Small focus : 25 mA, big focus 50 mA 75 mA 100 mA 125 mA (grading)
Time
0.04 ~ 6.3 s 23   .0.04 ~ 6.3 s, 23 grades together
High-voltage transformer unit
Capacity
             7 KV                        8.4 KVA
Max.Dc output voltage
             90 KV                     100 KV
Max.Dc output current
            100 mA                  125 mA
X-Ray tube
Model
XD4-2.9/100
Focus
1.8 mm   4.3 mm/small focus : 1.8 mm big focus: 4.3 mm
(YZ-SCIII) Photographic bed
Ray - Filter
1960 mm x 660 mm x 700 mm
(YZ-SCIII)
N28 / Grid density N28
F0 100 cm / Convergence distance fo 100 cm
R8 / Grid ratio r8
Pillar of X-ray source unit
Moving in length (along the bottom track)
> 1350 mm
Moving in breadth
       > 360 mm
Moving up and down
720 ~ 1800 mm
Max size cassette for photograph
356 x 432 mm (14” x 17”
  
MAX CAPACITY OF PHOTOGRAPY
Focus of X-ray tube
Photograph mA
Max photograph KV
Max allowable time
Small focus
25 mA
90 KV
100 KV
1.0 s
Big Focus
50 mA
90KV
95 KV
6.3 s
75 mA
90 KV
95 KV
5 s
100 mA
85 KV
90 KV
3.2 s
125 mA
85 KV
1.0 s
https://drive.google.com/file/d/1jepWUWxRlg-Jwx038tHZxs8K0aDButSH/view?usp=sharing